FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-29
51
You are at the console of an open systems interconnection (OSI)
server attached to the switch reporting the problem. If an incident
occurs on the Fibre Channel link between the switch and server, a
link incident record is generated and sent to the server using the
reporting procedure defined in T11/99-017v0.
Was a link incident record generated and sent to the switch-attached
OSI server?
YES NO
↓ Perform switch fault isolation at the management server or
customer-supplied server running the EFCM Lite application.
Go to step 20.
52
The link incident record provides the attached switch port number(s)
and one or more of the following event codes and messages. Record
all event codes that may relate to the reported problem.
581 - Link interface incident - implicit incident.
582 - Link interface incident - bit-error threshold exceeded.
583 - Link failure - loss of signal or loss of synchronization.
584 - Link failure - not-operational primitive sequence (NOS)
received.
585 - Link failure - primitive sequence timeout.
586 - Link failure - invalid primitive sequence received for the
current link state.
Were one or more event codes found?
YES NO
↓ Perform switch fault isolation at the management server or
customer-supplied server running the EFCM Lite application.
Go to step 20.
Go to Table 3-3 on page 3-3 to interpret event codes. Exit MAP.