FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-27
44
Inspect the switch for indications of being powered on, such as:
• At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
• Illuminated LEDs adjacent to Fibre Channel ports.
• Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
↓ A power distribution problem is indicated. Go to step 38 to
obtain event codes. If no event codes are found, go to MAP
0100: Power Distribution Analysis on page 3-30. Exit MAP.
A faulty PWR LED is indicated, but switch and Fibre Channel port
operation is not disrupted. The LED is connected to CTP card
circuitry, and if this problem is a concern to the customer, the switch
must be replaced. Exit MAP.
45
Is the amber ERR LED at the switch front bezel blinking?
YES NO
↓ Go to step 47.
46
Unit beaconing is enabled for the switch.
a. Consult the customer and next level of support to determine the
reason unit beaconing is enabled.
b. Disable unit beaconing.
1. At the Hardware View (Figure 3-10 on page 3-20), right-click
the front bezel graphic (away from a FRU). A pop-up menu
appears.
2. Click the Enable Unit Beaconing option. The check mark
disappears from the box adjacent to the option, and unit
beaconing is disabled.