FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-22
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Inspect the switch for a yellow triangle that overlays the FRU
graphic and indicates FRU beaconing is enabled.
Inspect ports for a yellow triangle (attention indicator) that
overlays the port graphic.
Does a yellow triangle overlay the switch or FRU graphic?
YES NO
Go to step 35.
34
Beaconing is enabled for the FRU.
a. Consult the customer and next level of support to determine the
reason FRU beaconing is enabled.
b. Disable FRU beaconing.
1. At the Hardware View (Figure 3-10 on page 3-20), right-click
the FRU graphic. A pop-up menu appears.
2. Click the Enable Beaconing option. The check mark
disappears from the box adjacent to the option, and FRU
beaconing is disabled.
Was FRU beaconing enabled because FRU failure or degradation
was suspected?
YES NO
The switch appears operational. Exit MAP.
Go to step 20 and perform fault isolation again (through the
management server or customer-supplied server).
35
Does a yellow triangle (attention indicator) overlay a port graphic?
YES NO
Go to step 37.
36
Inspect the port state and LED status for all ports with an attention
indicator.
a. Double-click a port to open the Port Properties dialog box
(Figure 3-11 on page 3-23).