FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-19
25
Ensure the switch is connected to facility AC power. Inspect the
switch for indications of being powered on, such as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
A power distribution problem is indicated. Go to step 38 to
obtain event codes. If no event codes are found, go to MAP
0100: Power Distribution Analysis on page 3-30. Exit MAP.
26
At the front of the switch, inspect the amber ERR LED.
Is the LED illuminated?
NO YES
A FRU failure or link incident is indicated. Go to step 38 to
obtain event codes that identify the failure. Exit MAP.
27
A switch-to-server Ethernet link failure is indicated.
Go to step 38 to obtain event codes. If no event codes are found,
go to MAP 0400: Loss of Server Communication on page 3-51.
Exit MAP.
28
Is a red diamond (failure indicator) associated with the icon
representing the switch reporting the problem?
YES NO
Go to step 30.