FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-16
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
1. The green LCD panel illuminates.
2. The green hard disk drive (HDD) LED blinks momentarily,
and processor speed and random-access memory
information display momentarily at the LCD panel.
3. After a few seconds, the LCD panel displays the following
message pertaining to boot sequence selection (Figure 3-7):
Figure 3-7 LCD Panel During Boot Sequence
4. Ignore the message. After ten seconds, the server performs
the boot sequence from the basic input/output system
(BIOS). During the boot sequence, the server performs
additional POSTs and displays the following operational
information at the LCD panel:
•Host name.
System date and time.
LAN 1 and LAN 2 IP addresses.
Fan 1, fan 2, fan 3, and fan 4 rotational speed.
Central processing unit (CPU) temperature.
Hard disk capacity.
Virtual and physical memory capacity.
d. After successful POST completion, the LCD panel displays a
Welcome!! message, then continuously cycles through and
displays server operational information.
e. After rebooting the server at the LCD panel, log on to the
management server’s Windows 2000 desktop through a LAN
connection to a browser-capable PC. Refer to Access the
Management Server Desktop on page 2-55 for instructions.The
SAN management application starts and the SANavigator Log In
or EFCM Log In dialog box displays (Figure 3-8 on page 3-17).
Boot from LAN?
Press <Enter>