FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-11
b. Inspect the Beaconing and Operational State fields.
Does the Beaconing field display an On message?
YES NO
Go to step 13.
12
Port beaconing is enabled.
a. Consult the customer and next level of support to determine the
reason port beaconing is enabled.
b. Disable port beaconing:
1. At the View panel, select Operations at the left side of the
panel. The Operations panel opens with the Port Beaconing
page displayed.
2. Click the Beaconing State check box for the port. The check
mark disappears and port beaconing is disabled.
3. Return to the View panel (Port Properties tab).
Continue to the next step.
13
At the View panel, does the Operational State field display a
Segmented message?
NO YES
Port segmentation is indicated. Go to step 18 to obtain event
codes. If no event codes are found, go to MAP 0700: Fabric,
ISL, and Segmented Port Problem Determination on
page 3-93. Exit MAP.
14
At the View panel, does the Operational State field display a message
indicating a port problem?
NO YES
Go to step 18 to obtain event codes. If no event codes are
found, go to MAP 0600: Port Failure and Link Incident
Analysis on page 3-74. Exit MAP.