Diagnostics
3-5
423 CTP firmware download initiated. No action required.
426 Multiple ECC single-bit errors occurred. Go to MAP 0500.
433 Non-recoverable Ethernet fault. Go to MAP 0500.
440 Embedded port hardware failed. Go to MAP 0500.
442 Embedded port anomaly detected. No action required.
445 ASIC detected a system anomaly. No action required.
453 New feature key installed. No action required.
506 Fibre Channel port failure. Go to MAP 0600.
507 Loopback diagnostics port failure. Go to MAP 0600.
508 Fibre Channel port anomaly detected. No action required.
510 SFP optical transceiver hot-insertion initiated. No action required.
512 SFP optical transceiver nonfatal error. Go to MAP 0600.
513 SFP optical transceiver hot-removal completed. No action required.
514 SFP optical transceiver failure. Go to MAP 0600.
523 FL_Port open request failed. No action required.
524 No AL_PA acquired. No action required.
525 FL_Port arbitration timeout. No action required.
581 Implicit incident. Go to MAP 0600.
582 Bit error threshold exceeded. Go to MAP 0600.
583 Loss of signal or loss of synchronization. Go to MAP 0600.
584 Not operational primitive sequence received. Go to MAP 0600.
585 Primitive sequence timeout. Go to MAP 0600.
586 Invalid primitive sequence received for current link state. Go to MAP 0600.
810 High temperature warning (CTP thermal sensor). Go to MAP 0500.
811 Critically hot temperature warning (CTP thermal sensor). Go to MAP 0500.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code Explanation Action