FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-4
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
151 Fabric configuration failure. Go to Collect Maintenance Data
on page 4-44.
200 Power supply AC voltage failure. Go to MAP 0100.
201 Power supply DC voltage failure. Go to MAP 0100.
203 Power supply AC voltage recovery. No action required.
204 Power supply DC voltage recovery. No action required.
206 Power supply removed. Replace FRU.
207 Power supply installed. No action required.
300 Cooling fan propeller failed. Go to MAP 0500.
301 Cooling fan propeller failed. Go to MAP 0500.
302 Cooling fan propeller failed. Go to MAP 0500.
303 Cooling fan propeller failed. Go to MAP 0500.
304 Cooling fan propeller failed. Go to MAP 0500.
305 Cooling fan propeller failed. Go to MAP 0500.
310 Cooling fan propeller recovered. No action required.
311 Cooling fan propeller recovered. No action required.
312 Cooling fan propeller recovered. No action required.
313 Cooling fan propeller recovered. No action required.
314 Cooling fan propeller recovered. No action required.
315 Cooling fan propeller recovered. No action required.
400 Power-up diagnostic failure. Go to MAP 0200.
410 Switch reset. No action required.
411 Firmware fault. Go to MAP 0200.
412 CTP watchdog timer reset. Go to Collect Maintenance Data
on page 4-44.
421 Firmware download complete. No action required.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code Explanation Action