FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
2
2-120
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Installation Tasks
g. Type the SAN management application default user ID and
password and select a server or IP address from the Network
Address drop-down list.
NOTE: The default SAN management application user ID is
Administrator and the default password is password. The user
name and password are case-sensitive.
h. Click Login. The application opens and the SANavigator or
EFCM main window appears (Figure 2-68 on page 2-73).
7. Remove the base restore CD from the CD-RW drive and store the
CD in a safe location. Insert a blank rewritable CD into the
CD-RW drive and format the CD. Refer to step 1 for formatting
instructions.
8. Go to Task 21: Cable Fibre Channel Ports below.
Task 21: Cable Fibre Channel Ports
Perform this task to connect devices to the switch. To cable Fibre
Channel ports:
1. Route fiber-optic jumper cables from customer-specified Fibre
Channel devices, FC-AL devices, or fabric switches to ports at the
front of the switch.
2. Connect device cables to SFP optical port transceivers. Start
with port 0 (far right) and continue sequentially to the left
through port 23.
3. Perform one of the following:
• If the switch is installed on a table or desk top, bundle and
secure the Fibre Channel cables as directed by the customer.
• If the switch is installed in a customer-supplied equipment
rack, bundle Fibre Channel cables from the switch and other
equipment (groups of 16 maximum), and secure them as
directed by the customer.
• If the switch is installed in a McDATA Fabricenter equipment
cabinet, bundle Fibre Channel cables from the switch and
other equipment (groups of 16 maximum), and secure them in
the cable management area at the front-left side of the cabinet.