FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
2
2-110
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Installation Tasks
Figure 2-100 Configure OpenTrunking Dialog Box
3. Perform one of the following:
• To enable OpenTrunking, click the Enable OpenTrunking check
box to add a check mark. Go to step 4 to set the congestion
threshold for each port.
• To disable OpenTrunking, click the Enable OpenTrunking check
box to remove the check mark, then click Activate to enable the
change and close the dialog box.
4. For each switch port:
a. Click the check box in the Use Algorithmic Threshold column. A
check mark appears in the box and a calculated default value
appears (1% to 99%) in the associated field in the Threshold %
column. If the default value is enabled, a value cannot be
entered in the Threshold % column.
b. Ensure the check box in the Use Algorithmic Threshold column
is blank. At the associated field in the Threshold % column,
type a percentage value from 1% to 99%.