FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

2
2-98
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Installation Tasks
1. Ensure the SANtegrity binding PFE key is installed and
configured. For instructions, refer to Task 16: Configure PFE Key
(Optional) on page 2-82.
2. At the Hardware View, select Switch Binding, then Change State
from the Configure menu. The Switch Binding - State Change dialog
box displays (Figure 2-89).
Figure 2-89 Switch Binding - State Change Dialog Box
3. Perform one of the following:
To enable switch binding, click the Enable Switch Binding check
box to add a check mark. Go to step 4 to set the connection
policy.
To disable switch binding, click the Enable Switch Binding
check box to remove the check mark, then click Activate to
enable the change and close the dialog box.
4. Select a Connection Policy radio button as follows:
Restrict E_Ports - Select this button to restrict connections
from specific fabric elements to switch E_Ports. WWNs can be
added to the membership list to allow element connection and
removed from the list to prohibit element connection. Devices
are allowed to connect to any F_Port or FL_Port without
restriction.
Restrict F_Ports - Select this button to restrict connections
from specific devices to switch F_Ports or FL_Ports. WWNs
can be added to the membership list to allow device
connection and removed from the list to prohibit device
connection. Fabric switches are allowed to connect to any
E_Port without restriction.