FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

2
Installation Tasks
2-51
Installation Tasks
Task 7: Configure Server Password and Network Addresses
Verify the type of LAN installation with the customer’s network
administrator. If the management server or Fabricenter equipment
cabinet is installed on a dedicated LAN, network information does
not require change. Change the default password for the server’s
LCD panel (if required by the customer), then go to Task 8: Configure
Management Server Information on page 2-55.
If the management server or Fabricenter equipment cabinet is
installed on a public LAN segment, the default password for the
server’s LCD panel and the following transmission control protocol
internet protocol (TCP/IP) network information must be changed to
conform to the customer’s LAN addressing scheme:
IP address.
•Subnet mask.
NOTE: At some customer installations, TCP/IP addresses for the
management server may be allocated automatically using dynamic host
configuration protocol (DHCP).
Configure Password
To configure a new LCD panel password:
1. At the management servers LCD panel, press ENTER. The
Welcome!! or operational information message changes to the
following (Figure 2-33):
Figure 2-33 LCD Panel (Password Entry)
2. Using the button to increment a digit, the button to
decrement a digit, the button to move the cursor left,
and the button to move the cursor right, input the default
password (9999), and press ENTER. The LAN 1 Setting??
message appears at the LCD panel.
3. Press the button several times until the Change Password?
option appears at the LCD panel, then press ENTER. The
following message appears (Figure 2-34 on page 2-52):
Input Password:
0****