FW 05.01.00 and SW 07.02.00 hp StorageWorks HA-Fabric Manager Server Installation Guide
Rack Mount Instructions
92 HA-Fabric Manager Server Installation Guide
Rack Mount the HAFM Server
This section describes procedures to:
■ Assemble and attach the front and rear brackets to the equipment cabinet.
■ Attach the left and right slide rails to the server.
■ Install the server in the equipment cabinet.
Attach Front and Rear Brackets
To assemble the front and rear brackets and attach the assemblies to the
equipment cabinet:
1. Consult with the customer and determine the cabinet installation position for
the server. The server is 1.75 inches or one rack unit (1U) high.
2. The depth of the equipment cabinet determines if the long rear mounting
bracket or short rear mounting bracket is used.
a. Using a tape measure (provided by installation personnel), measure and
record the depth of the left side of the cabinet from the inside of the front
vertical rack-mounting standard to the inside of the rear vertical
rack-mounting standard.
b. Measure and record the depth of the right side of the cabinet from the
inside of the front vertical rack-mounting standard to the inside of the rear
vertical rack-mounting standard.
3. Using a #2 Phillips screwdriver and eight (8) of the ten pan-head Phillips
screws (#10 x 1/2) and, if you are installing the server in an HP 9000, 10000
or 11000 rack, eight (8) square alignment washers, attach four (4) three-hole
bar nuts to the rack-mounting standards as follows:
a. Align each three-hole bar nut with the rack-mounting standard as shown
in Figure 80. Ensure each bar nut is mounted on the inside of the
rack-mounting standard with narrow side (drilled holes-to-edge side)
facing to the inside of the cabinet.
Note: Ensure the bar nut screw washers do not overlap the inside edges of the
rack-mounting standards and mounting brackets. Washer overlap may interfere with
slide rail operation.