FW 05.01.00 and SW 07.02.00 hp StorageWorks HA-Fabric Manager Server Installation Guide
Configuration
69HA-Fabric Manager Server Installation Guide
To enable the call-home feature on individual Directors and Edge Switches,
perform the following for each Director and Edge Switch:
1. From the HAFM main window, double-click on the icon for the device.
The Hardware View for the device is displayed.
2. On the menu bar, select Maintenance > Enable Call Home Notification.
3. Place a check mark in the Enable Call Home Event Notification option.
4. See “Test Remote Notification” on page 72 for instructions on testing the
call-home feature.
Configure E-Mail Event Notification
In addition to call-home functionality, notifications of many events can be sent via
e-mail. You can configure up to five e-mail addresses for administrators or others
who should be notified of significant product events.
The events that initiate e-mail event notification are specific to each managed
product. Some examples of events that initiate e-mail event notification are:
■ A change in system operational status.
■ Problem detection, such as a failed field-replaceable unit (FRU).
■ Problem correction.
■ A change in state that requires user attention or that requires a report to a
product administrator or service representative.