fw 05.01.00 and sw 07.01.00 edge switch 2/24 product manager user guide
Product Manager Overview
49Edge Switch 2/24 Product Manager User Guide
status of the switch and the messages display to provide more description of menu
options as you move the cursor over the options under menu bar menus. Refer to
Table 2 for the meaning of these status symbols and of the corresponding alert text
that displays in the Edge-24 Status table at the top of the Hardware View in the
view panel.
If a gray square displays in the status bar (no Ethernet connection), a reason for
the status displays in the Status table at the top of the Hardware View. Refer to
“No Link Status” on page 59 for details.
Table 2: Product Manager status bar symbols
Symbol
Status
Bar
Switch Status Table
Text
Meaning
Green
Circle
Fully Operational All components and installed ports
are operational; no failures.
Yellow
Triangle
Redundant Failure A redundant component has
failed, such as a power supply,
and the backup component has
taken over operation.
Minor Failure A failure occurred which has
decreased the switch’s operational
ability. Normal switching
operations are not affected.
One or more ports failed, but at
least one port is still operational.
A fan has failed or is not rotating
sufficiently.
Blinking
Red and
Yellow
Diamond
NOT OPERATIONAL A critical failure prevents the
switch from performing
fundamental switching operations.
All fans failed.
All installed ports failed.
Both power supplies failed.
Gray
Square
Never Connected
Link Timeout
Protocol Mismatch
Duplicate Session
Unknown Network
Address
Incorrect Product Type
Switch status is unknown. This
occurs if the Ethernet network
connection between the HAFM
server and the switch cannot be
established or if the CTP fails.
Refer to “No Link Status” on
page 59 for details on the status
table text.