HP StorageWorks SAN Product Support Tables for the SAN Design Reference Guide

6
IMPORTANT: Refer to Table 1 for the list of supported switch models and versions.
Table 4: SAN Support Updates to the Heterogeneous Open SAN Design Reference Guide, Table 4-10
Platform/Storage System SAN Attachment Summary – with HBA Drivers and Firmware Revisions for
MSA1000 and RA4100/4000
Platform or Operating System
Storage System in ( )
Platform HBA
SAN Attachment
HBA Driver &
Firmware
Revision
(Minimum)
Multi-Path
Support
MSA1000
(FW: 1.16)
SAN
Attachment
RA4100,
RA4000 (FW:
2.60)
SAN Attachment
Red Hat Linux 7.0, 7.1
SuSE Linux 7.1
RA4100/4000:
FL-Port
120186-B21
223180-B21
v1.3.6 N/A N/A
FL-Port to SAN
Switch
Microsoft Windows 2000 SP2 (MSA)
Microsoft Windows NT 4.0 SP6a (MSA)
Microsoft Windows 2000 SP1 (RA)
Microsoft Windows NT 4.0 SP6a (RA)
MSCS
MSA1000:
F-Port
FCA-2101
RA4100/4000:
FL-Port
120186-B21
223180-B21
MSA1000:
W2K: v5-4.82a5
NT: v4-4.82a5
FW: 3.82a1
BIOS: 1.60a5
RA4100/4000:
W2K: v5.12.16.69
NT: v4.28.16.69
MSA1000:
Secure Path
3.1b
RA4100/4000:
Compaq
Redundancy
Manager v1.30a
Secure Path
3.1a
F-Port to
SAN Switch
FL-Port to SAN
Switch or to an
FC-AL Switch
cascaded to a
SAN Switch
Novell Netware 5.1
Clusters 1.01
FL-Port
120186-B21
223180-B21
Secure Path
v3.0b
N/A
FL-Port to SAN
Switch or to an
FC-AL Switch
cascaded to a
SAN Switch
Copyright © August 2002, Hewlett Packard AV-RNZEI-TE