HP StorageWorks SAN Product Support Tables for the SAN Design Reference Guide
10
Table 7: SAN Support Platform/Storage System SAN Attachment Summary for ACS 8.6 Only
(Use with Table 6 Switches and Switch Firmware) (Sheet 3 of 3)
Platform or Operating System Platform HBA
SAN Attachment
HBA Driver &
Firmware
Revision
(Minimum)
Multi-
Path
Support
MA6000, MA8000, RA8000, EMA12000,
EMA16000, ESA12000 SAN Attachment
Microsoft Windows 2000 SP2
Windows NT 4.0 SP6a
MSCS
F-Port
KGPSA-BC
380574-001
W2K:
v5-4.53a7
NT: v4-4.53a7
FW: v3.20x7
v3.1a SP1
v3.1a
F-Port using FABRIC topology
Transparent or Multiple-Bus Failover
SCSI-2 Mode Command Console LUN
disabled or SCSI-3 Mode
Connection name O/S parameter: WINNT
F-Port
KGPSA-CB
W2K:
v5-4.53a7
NT: v4-4.53a7
FW: v3.82a1
Boot Bios:
1.60a4
Microsoft Windows 2000
Datacenter 1.1a
MSCS
F-Port
KGPSA-BC
380574-001
W2K:
v5-4.52a9
FW: v3.20x7
Secure
Path v3.1a
or
v3.1a SR1
or
v3.1a SP1
F-Port using FABRIC topology
Transparent or Multiple-Bus Failover
SCSI-2 Mode Command Console LUN
disabled or SCSI-3 Mode
Connection name O/S parameter: WINNT
F-Port
KGPSA-CB
W2K:
v5-4.52a9
FW: v3.81a1
Boot Bios:
1.60a4
Novell NetWare 4.2, 5.1, 6.0
5.1 with Clusters 1.01
6.0 with Clusters 1.06
FL-Port
120186-B21
(64-bit)
CFQFC.HAM
v2.5.2
Secure
Path v3.0b
(5.1, 6.0)
F-Port using FABRIC topology
Transparent (4.2, 5.1, 6.0) or Multiple-Bus
Failover (5.1, 6.0)
SCSI-2 Mode Command Console LUN
enabled/disabled or SCSI-3 Mode
Connection name O/S parameter: NETWARE
FL-Port
223180-B21
(32-bit)
SGI IRIX 6.5.11, 6.5.12
F-Port
SGI PCI-FC-1POPT
SGI XT-FC-1POPT
Native – Based
on the O/S
revision
N/A
F-Port using FABRIC topology
Transparent Failover
SCSI-2 Mode Command Console LUN
disabled or SCSI-3 Mode
Connection name O/S parameter: SGI
Sun Solaris 2.6 (32-bit)
Sun Solaris 7, 8 (32/64-bit)
SUN Clusters v2.2 w/ 2.6, 7, 8
Veritas Clusters 1.2.1
F-Port 380575-001
(32-bit Sbus)
v2.5.9.03
FW: v13.3.7
Secure
Path
v3.0
F-Port using FABRIC topology
Transparent or Multiple-Bus Failover
SCSI-2 Mode Command Console LUN
enabled/disabled or SCSI-3
F-Port 123503-001
(64-bit Sbus)
v2.5.9.03
FW: v13.3.7
F-Port 380576-001
(32-bit PCI)
v2.5.9.03
FW: v3.03
Sun Solaris 8 (64-bit cPCI)
F-Port
254457-B21
(64-bit cPCI)
v3.18
FCODE: v1.18.5
FW: 2.1.38
N/A
F-Port using FABRIC topology
Transparent Failover
SCSI-2 Mode Command Console LUN
enabled/disabled or SCSI-3
Copyright © August 2002, Hewlett Packard AV-RNZEI-TE