HP StorageWorks Director and Edge Switch release notes (5697-8176, April 2009)
Determining current firmware version
This section describes how to determine the current version of firmware for an Edge Switch or Director
using HAFM, HAFM Basic, Embedded Web Server, or the CLI.
Using HAFM
To determine the current version using HAFM:
1. Open the Element Manager for the Edge Switch or Director.
2. Select Product > Properties from the menu bar.
The firmware version appears in the dialog box.
Using HAFM Basic
To determine the current version using HAFM Basic (firmware 08.xx.xx or later):
1. Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
The Fabric View appears.
2. Click Details for the Edge Switch or Director.
The Product > Hardware view appears, displaying the firmware version.
Using Embedded Web Server
To determine the current version using Embedded Web Server (firmware 07.xx.xx or earlier):
1. Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
2. Select View from the navigation panel on the left.
3. Select the Unit Properties tab.
The firmware version appears in tab.
Using the CLI
To determine the current version using the CLI:
1. Telnet to the Edge Switch or Director using the IP address of the switch.
2. Enter the show system command.
The firmware version appears in the system information display.
Supersedes history
This version supersedes firmware 09.09.00.
Effective date
April 2009
Director and Edge Switch release notes 17