HP StorageWorks Director and Edge Switch release notes (5697-8176, April 2009)

configuration is preserved and a system outage is avoided. This issue has been resolved with firmware
05.02.00-13 and later.
NOTE:
You must have maintenance authorization rights to access the HAFM Product/Element Manager menu
options used in this procedure.
To safely upgrade firmware on a Director:
1. Upgrade HAFM software on the HAFM Server/Appliance to 07.01.00 (minimum).
2. Download firmware 05.02.00-13 by selecting Firmware Library from the Product Manager
Maintenance menu.
3. Back up the Director configuration by selecting Backup & Restore Configuration from the Product
Manager Maintenance menu.
NOTE:
Step 4 is not required if you are upgrading from 05.
xx
.
xx
or later.
4. Using the Product Manager, execute a CTP swap:
a. From the Product/Element Manager Hardware view, verify that an amber LED indicator is
not displayed for either CTP card.
b. Right-click the CTP card you believe to be active, and then select FRU Properties. Verify that
it is the active CTP card.
c. Right-click the active CTP card, and then select Switchover.
The Director loses its Ethernet connection for a short time during the switchover process.
When switchover occurs, the green LED illuminates on the backup CTP card to indicate that
it is now the active card.
5. Upgrade the firmware to 05.02.00-13 on each Director by selecting Send in the Firmware Library
dialog box.
Upgrading firmware on an Edge Switch from 04.xx.xx to 05.xx.xx
An issue has been identified in release 04.xx.xx if the contents of the NVRAM on the CTP are corrupted.
Once the configuration has been loaded, this corruption is not detected until an IPL/IML, power cycle,
or firmware code load. If the NVRAM on the CTP has corrupted contents, the firmware load can cause
the configuration to reset to factory defaults, which can cause a system outage.
Edge Switch products already running 05.01.00 or later continually validate the NVRAM configuration,
so risk of an outage is extremely low. For Edge Switch products running an earlier version of firmware,
the risk of an outage increases due to the NVRAM issue. If an outage compromises system integrity,
HP recommends that the Edge Switch firmware upgrade be a scheduled maintenance action that
anticipates the failure of switch connectivity. This issue has been resolved with firmware 05.02.00-13
and later.
To safely upgrade firmware on an Edge Switch:
1. Upgrade HAFM software on the HAFM Server/Appliance to 07.01.00 (minimum).
2. Download firmware 05.02.00-13 by selecting Firmware Library from the Product Manager
Maintenance menu.
10