HP StorageWorks Director and Edge Switch Release Notes (09.09.09) (5697-0776, November 2010)
Affected productsDescription
AllIf the line speed of the Ethernet port was set to 10 Mb/s and half duplex using the
CLI, in subsequent queries using config ip show the line speed would be shown
as Unknown.
Director 2/140
nl
M4700, M4400
In a fabric where a zone member is in more than one RD zone, the control processor
(CTP) could exhibit a failure and generate an Event 411, Firmware Fault with event
data of 80 48.
Director 2/140
nl
M4700, M4400
In a switch that supports dual stack (IPv4 and IPv6), when the switch processes ICMP
redirect messages, the backup CTP could continuously reboot and generate an Event
411, Firmware Fault with event data C0.
AllThe Maintenance/Serial port could stream MS_ROUTER_PRIVATE::_ms_pro-
cess_logo messages.
Director 2/140,
M4700, M4400
When the zoning database was very large, and the zoneset was activated or merged
with another zoneset, M-series switches that support Frame Redirection zones rejected
the zoning change, reporting the blocked by another transaction fault.
When using DCFM for zoning changes, this caused a configuration save operation
failure.
Director 2/140When a port was unblocked in a Director 2/140, the user could receive an Event
411 Firmware Fault with event data C0, resulting in a CTP fault and switchover.
AllWhen accessing the switch using the HAFM Basic interface (embedded GUI), No
Info links could erroneously appear under Health Status in the Port List display.
Also, selecting links under Health Status would not display SFP information (temper-
ature, voltage, current Rx and Tx power).
Director 2/140When taking a data collection from a Director 2/140, an Event 411 Firmware
Fault with event data C0 could occur due to an internal buffer overrun.
Compatibility and interoperability
This section describes Edge Switch and Director product compatibility.
HAFM/EFCM/DCFM and firmware compatibility
Table 4 lists the minimum versions of HAFM/EFCM/DCFM that run with the Edge Switch and Director
firmware versions.
Table 4 HAFM/EFCM/DCFM and firmware compatibility
HAFM/EFCM/DCFM versionFirmware version
DCFM 10.3.0 or later (recommended)
EFCM 09.07.00
HAFM 08.09.01 minimum (some newer switch features not
managed)
09.07.02
1
09.09.05
09.09.06
09.09.08
09.09.09
1
Firmware 09.07.02 is supported only for fabrics that include the McDATA 4Gb SAN Switch for HP p-Class BladeSystem.
For the latest support, see the SPOCK website: http://www.hp.com/storage/spock
8