HP StorageWorks Director and Edge Switch Release Notes (09.09.08) (5697-0720, October 2010)

Affected productsDescription
Director 2/140
nl
M4700, M4400
In a switch that supports dual stack (IPv4 and IPv6), when the switch processes ICMP
redirect messages, the backup CTP could continuously reboot and generate an Event
411, Firmware Fault with event data C0.
AllThe Maintenance/Serial port could stream MS_ROUTER_PRIVATE::_ms_pro-
cess_logo messages.
Director 2/140,
M4700, M4400
When the zoning database was very large, and the zoneset was activated or merged
with another zoneset, M-series switches that support Frame Redirection zones rejected
the zoning change, reporting the blocked by another transaction fault.
When using DCFM for zoning changes, this caused a configuration save operation
failure.
Director 2/140When a port was unblocked in a Director 2/140, the user could receive an Event
411 Firmware Fault with event data C0, resulting in a CTP fault and switchover.
AllWhen accessing the switch using the HAFM Basic interface (embedded GUI), No
Info links could erroneously appear under Health Status in the Port List display.
Also, selecting links under Health Status would not display SFP information (temper-
ature, voltage, current Rx and Tx power).
Director 2/140When taking a data collection from a Director 2/140, an Event 411 Firmware
Fault with event data C0 could occur due to an internal buffer overrun.
Compatibility and interoperability
This section describes Edge Switch and Director product compatibility.
HAFM/EFCM/DCFM and firmware compatibility
Table 4 lists the minimum versions of HAFM/EFCM/DCFM that run with the Edge Switch and Director
firmware versions.
Table 4 HAFM/EFCM/DCFM and firmware compatibility
HAFM/EFCM/DCFM versionFirmware version
DCFM 10.3.0 or later (recommended)
EFCM 09.07.00
HAFM 08.09.01 minimum (some newer switch features not
managed)
09.07.02
09.09.05
09.09.06
09.09.08
For the latest support, see the SPOCK website: http://www.hp.com/storage/spock
8