HP StorageWorks Director and Edge Switch Release Notes (09.09.08) (5697-0720, October 2010)
Fixes
Table 2 lists issues that have been fixed since the release of firmware 09.09.06. Table 3 lists issues
that have been fixed since the release of firmware 09.09.00.
Table 2 Fixes in this release
Affected productsDescription
AllWhen an Access Gateway device was connected to a standalone switch, HAFM
Basic (the embedded switch GUI) showed the connected device as offline with a
reason of Blocked temporarily, internal.
AllMixed fabrics (with B-series and M-series/McDATA switches) operating in IM2 interop
(McDATA Fabric ) mode did not support Frame Redirect zones with the default zone
enabled. This restriction was removed.
AllIn nonrestartable Frame Redirection mode, if a virtual initiator was taken offline, a
route still existed between the physical host and target.
AllIn an environment involving routed fabrics and encryption, where one or both of
the edge fabrics was an M-series/McDATA Interop fabric, if an initiator was attached
directly to an M-series/McDATA switch in the edge fabric, the host could lose access
to imported targets in the event the encryption switch went offline and then back
online.
AllRSCN was not sent to physical Host and Target for Virtual Initiator and Virtual Target
state changes when Frame Redirection Virtual Initiator/Virtual Target were part of
a regular zone set.
AllUsing restartable Frame Redirection, when just the virtual initiator was taken offline,
the virtual target PID was sent to the host in the RSCN instead of the target PID.
AllIn an IM3 (McDATA Open Fabric ) mode fabric where both the host and target
were connected to M-series/McDATA switches, and the Frame Redirection policy
is nonrestartable, routes still existed from host to target when a virtual initiator was
taken offline.
AllA Virtual Initiator responded to physical target query even when the Virtual Target
was down.
AllWith Virtual Target offline, GID_PN or GID_NN name server queries would return
Virtual Initiator PID instead of Host PID.
AllWith a Virtual Initiator offline, the GNN_ID, GID_PN and GID_NN name server
query responses all returned values to the host when they should have been rejected.
AllWith Virtual Initiator offline, the GID_PN and GID_NN name server query responses
both returned the Virtual Target PID to the host instead of the target PID.
AllThe error message Blocked Temporarily, internal was shown for devices
on switch ports after a Power On Reset when the error message should have been
Blocked due to special (RD) zone.
Director 2/140After upgrading firmware to 09.09.06, CTP faults could be encountered (events
410, 414, and 411), and C0 faults could occur followed by the CTP coming back
online. This only happened when an IP source was sending the switch an ICMP re-
direct packet over TCP/IP.
6