HP StorageWorks Director and Edge Switch Release Notes (09.09.08) (5697-0720, October 2010)
Determining the current firmware version
This section describes how to determine the current firmware version for an Edge Switch or Director
using DCFM/EFCM/HAFM, HAFM Basic, Embedded Web Server, or the CLI.
Using DCFM/EFCM/HAFM
To determine the current firmware version using DCFM/EFCM/HAFM:
1. Open the Element Manager for the Edge Switch or Director.
2. Select Product > Properties from the menu bar.
The dialog box displays the firmware version.
Using HAFM Basic
To determine the current firmware version using HAFM Basic (firmware 08.xx.xx or later):
1. Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
The Fabric View appears.
2. Click Details for the Edge Switch or Director.
The Product > Hardware view appears, displaying the firmware version.
Using Embedded Web Server
To determine the current firmware version using Embedded Web Server (firmware 07.xx.xx or earlier):
1. Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
2. Select View from the navigation panel on the left.
3. Click the Unit Properties tab.
The tab displays the firmware version.
Using the CLI
To determine the current firmware version using the CLI:
1. Using the IP address of the switch, Telnet to the Edge Switch or Director.
2. Enter the show system command.
The firmware version appears in the system information display.
Supersedes history
This version supersedes firmware 09.09.06.
Effective date
September 2010
Director and Edge Switch Release Notes (09.09.08) 19