HP StorageWorks Director and Edge Switch Release Notes (09.09.08) (5697-0720, October 2010)
Workaround
: The slower rerouting of data by Open Trunking can be tolerated and corrects itself.
This can be avoided by disabling Reroute Delay when using Open Trunking.
Devices may be blocked in mixed M-series and B-series fabrics using Frame
Redirection
M-series switches in a fabric with B-series switches using Frame Redirection zoning may block all
attached devices with the reason indication Blocked Temporarily, Internal. This can occur
when users power-cycle the M-series switch while it is participating in a fabric with Frame Redirection
zoning (a capability used for B-series application or encryption services).
Workaround
: If the switch is still participating in the fabric with Frame Redirection, issue the cfgsave
command from a B-series switch with the Frame Redirection zone in its defined zone database. If the
M-series switch is no longer attached to the fabric with Frame Redirection zoning, issue the
Config.Zoning.deleteSplZoneSet command via CLI to the M-series switch.