HP StorageWorks Director and Edge Switch Release Notes (09.09.08) (5697-0720, October 2010)
HAFM upgrade required for firmware 09.09.08
Consider the following HAFM requirements for firmware 09.09.08:
• If you are using the 1U rack-mount HAFM Appliance to manage the Edge Switch or Director, the
minimum HAFM version required is 08.09.01. This HAFM software is provided on the HP Stor-
ageWorks HA-Fabric Manager documentation and software CD (Part Number 516-000024-720).
• This minimum version of HAFM allows you to manage Edge Switches or Directors running firmware
09.09.08. However, to manage all of the newer switch features and enhancements, you may
upgrade to EFCM software 09.07.00. To migrate from HAFM to EFCM, you must first upgrade
to HAFM 08.09.01. An upgrade kit for HAFM 08.09.01 (Part Number A7490A) is available for
owners of a licensed version of HAFM. Contact your HP-authorized service representative to obtain
a HAFM upgrade kit. This HAFM upgrade is also available on the following HP website:
http://h18006.www1.hp.com/storage/networking/index.html
Select Retired Products, navigate to your switch model, and then select Download drivers and
software.
• HP recommends using DCFM Enterprise or DCFM Professional Plus version 10.3.0 or later to
manage your M-series Edge Switches or Directors. You can migrate from an installation of EFCM
09.07.00 to DCFM Enterprise 10.3.0.
Alternatively, you can perform the firmware upgrade directly to the Edge Switch or Director using the
switch's HAFM Basic management interface.
For more information about upgrading software versions, see the HP StorageWorks HA-Fabric Manager
user guide.
M-series and B-series switch interoperability
For details on compatible firmware versions, management software EFCM or Data Center Fabric
Manager (DCFM) Enterprise versions, and other requirements for M-series and B-series switch
interoperability, see the latest application notes under Application Notes > Fabric Interoperability,
available on the following HP website:
http://www.hp.com/storage/spock
Important information
This section provides information that you should consider before using Edge Switches or Directors
running firmware 09.09.08.
Master log does not display port number
For port offline and online messages in the Master log in HAFM or EFCM, the switch port number,
switch WWN, and connected device (node) WWN should be included in the message. However,
the switch WWN appears as the node WWN, and the node WWN is not included.
HAFM Basic issue with Mozilla browser
Access control list (ACL) IP entries are not validated in HAFM Basic when using Mozilla browser.