FA MIB
Object
Name
Type Product Mapping Access Description
*fcConnUnitS
ensorIndex
Unsigned
32
Not assessable. R A unique value among
all
fcConnUnitSensorEntrys
with the same value of
fcConnUnitId, in the
range between 1 and
fcConnUnitNumSensors[f
cConnUnitId].
FcConnUnitSe
nsorName
SnmpAd
minString
The module name of the FRU,
such as FAN, PWR or THM.
R A textual identification of
the sensor, intended
primarily for operator
use.
FcConnUnitSe
nsorStatus
INTEGER This value is evaluated from
FRU status. The active, backup
and update-busy states are
mapped to ok(3). The failed
state is mapped to failed(5).
RThe status indicated by
the sensor. The values
are defined as follows:
unknown (1) – the unit
cannot determine the
status, other (2) -- the
status does not fit any of
the remaining values, ok
(3) – indicates good
status, warning (4) –
indicates the unit needs
attention, failed (5) B
indicates the unit is
non-functional.
FcConnUnitSe
nsorInfo
SnmpAd
minString
The serial number of the FRUs.
This is not supported if the
module is failed.
R Miscellaneous static
information about the
sensor, such as its serial
number.