FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)
SNMP Support
95SNMP Reference for Directors and Edge Switches
Firmware Table
The revisions table lists the revisions supported by the associated connectivity
units.
Sensor Table
The sensor table lists the sensors (for fan and power supplies) supported by each
switch. For each switch, the table will contain a list of all fan and power supply
FRU positions, regardless of whether they are installed. When a FRU is not
installed, the UnitSensorStatus for that table entry will be unknown(1). When a
power supply or fan FRU is installed or removed, a sensor trap will be sent (if
enabled), which contains an index to the appropriate entry in this table, for the
affected FRU. Note that the number of entries in the table does not change when a
fan/power supply FRU is installed or removed.
FA MIB
Object
Name
Type Product Mapping Access Description
*fcConnUnitR
evsIndex
Unsigned
32
Not accessible R A unique value among
all fcConnUnitRevsEntrys
with the same value of
fcConnUnitId, in the
range between 1 and
fcConnUnitNumRevs[fcC
onnUnitId].
FcConnUnitRe
vsRevision
SnmpAd
minString
XX.XX.XX (The revision of the
switch).
R A vendor-specific value
identifying a revision of
a component of the
connectivity unit.
FcConnUnitRe
vsDescription
SnmpAd
minString
Switch Firmware Level R Description of a
component in the
fcConnUnit to which the
revision corresponds.