FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)
SNMP Support
94 SNMP Reference for Directors and Edge Switches
FcConnUnitC
ontact
SnmpAdminSt
ring
Contact
information for
this connectivity
unit.
Writable and
persistent across
IPL.
R/W Contact information for this
connectivity unit. The contact
information is intended to facilitate
contacting someone in case of
problems, questions, and so forth.
(for example, the help desk internal
to a company).
FcConnUnitLo
cation
SnmpAdminSt
ring
The physical
location of the
switch.
Writable and
persistent across
IPL.
R/W Location information for this
connectivity unit.
FcConnUnitEv
entFilter
FcEventSeverit
y
Writable and it
is set to the
default value of
info(8) after IPL.
R/W Defines the event severity that will be
logged by this connectivity unit. All
events of severity less than or equal
to fcConnUnitEventFilter are logged
in the fcConnUnitEventTable.
FcConnUnitN
umEvents
Unsigned32 Number of
events in the
fcConnUnitEvent
Table. It is
always <= 200,
the maximum
size of the event
table.
R Number of events currently in the
fcConnUnitEventTable.
FcConnUnitM
axEvents
Unsigned32 200. R Max number of events that can be
recorded at any one time in the
fcConnUnitEventTable.
FcConnUnitEv
entCurrID
Unsigned32 The current
event index is
used as the last
used event id.
R
The last used event id
(fcConnUnitEventIndex) recorded in
the fcConnUnitEventTable. When no
events are presently recorded in the
fcConnUnitEventTable, the value of
this object