FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)
SNMP Support
70 SNMP Reference for Directors and Edge Switches
fcFxPortIntermixSu
pported
INTEGER SNMP R A flag indicating whether the
Fx_Port supports an Intermixed
Dedicated Connection. The values
are defined as follows: yes(1) and
no(2).
This is fixed at no(2).
FcFxPortStackedC
onnMode
FcStackedConnM
ode
SNMP R A value indicating the mode of
Stacked Connect supported by the
Fx_Port.
This is fixed at none(1).
FcFxPortClass2Se
qDeliv
INTEGER SNMP R A flag indicating whether Class 2
Sequential Delivery is supported
by the Fx_Port. The values are
defined as follows: yes(1) and
no(2).
This is fixed at yes(1).
FcFxPortClass3Se
qDeliv
INTEGER SNMP R A flag indicating whether Class 3
Sequential Delivery is supported
by the Fx_Port. The values are
defined as follows: yes(1) and
no(2).
This is fixed at yes(1).
FcFxPortHoldTime MicroSeconds PCP R The maximum time (in
microseconds) that the Fx_Port
shall hold a frame before
discarding it if it is unable to
deliver the frame. The value 0
means that the Fx_Port does not
support this parameter.
This is equal to quarter of
E_D_TOV which is obtained from
PCP.
FcFxPortBaudRate Fc0BaudRate FPM R The FC-0 baud rate of the
Fx_Port.
One of these values, or no value
will be returned.
0x10, 1 Gbaud (100 MB/s)
0x20, 2 Gbaud (200 MB/s)
0x40 4 Gbaud (400 MB/s)