FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)

SNMP Support
69SNMP Reference for Directors and Edge Switches
FcFxPortFcphVersi
onLow
FcphVersion FC2 R Lowest or earliest version of
FC-PH that the Fx_Port is
configured to support. Since the
switch is not capable of changing
its support for FC-PH version, the
version reported is the one
currently in use for this port. If
there is no device logged in, the
value is 0. For values see
FcFxPortFcphVersionHigh” on
page 68.
FcFxPortBbCredit FcBbCredit PCP R The total number of receive
buffers available for holding
Class 1 connect-request, Class 2,
or 3 frames from the attached
NxPort. It is for buffer-to-buffer
flow control in the direction from
the attached NxPort (if
applicable) to Fport.
FcFxPortRxBufSize FcRxDataFieldSize LOGIN
SERVER
R The largest Data_Field Size (in
octets) for an FT_1 frame that can
be received by the Fx_Port.
This is fixed at 2112.
FcFxPortRatov MilliSeconds PCP R The Resource_Allocation_Timeout
Value configured for the Fx_Port.
This is used as the timeout value
for determining when to reuse an
NxPort resource such as a
Recovery_Qualifier. It represents
E_D_TOV (see next object) plus
twice the maximum time that a
frame may be delayed within the
Fabric and still be delivered.
FcFxPortEdtov MilliSeconds PCP R The E_D_TOV value configured
for the Fx_Port. The
Error_Detect_Timeout Value is
used as the timeout value for
detecting an error condition.
FcFxPortCosSuppo
rted
FcCosCap SNMP R A value indicating the set of
Classes of Service supported by
the Fx_Port.
This is fixed at CLASS_2 |
CLASS_3 (0x0C).