FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)
SNMP Support
24 SNMP Reference for Directors and Edge Switches
For the SNMPv2 trap PDU, the first and second variable bindings contain the
uptime and the trap OID, respectively. Following the uptime and trap OID are all
the variable bindings specified in the MIB for that particular trap.
EOS Trap Summary Table
This table shows the different kinds of traps supported by the switch EOS
firmware.
Note: All EOS traps are SNMPv1 format, regardless of MIB definition syntax.
Trap Severity
Sent
Because:
MIB Trap OID EOS HAFM
Generic
Authentication
Failure
N/A SNMP
request
from an
invalid
community
is received.
RFC-1157 YES NO
Generic Link Up N/A RFC-1157 YES NO
Generic Warm
Start
N/A Software
reset.
RFC-1157 YES NO
Generic Cold
Start
N/A Power up. RFC-1157 YES NO
ES Port Change N/A A change in
port status.
FCEOS 1.3.6.1.4.1.289.1 YES NO
ES Fru Change N/A A change in
FRU status.
FCEOS 1.3.6.1.4.1.289.2 YES NO
ES Invalid
Attachment
N/A Invalid
attachment
to a port.
FCEOS 1.3.6.1.4.1.289.3 YES NO
ES Threshold
Alert
N/A Threshold
specified in
threshold
table has
been
exceeded
for a port.
FCEOS 1.3.6.1.4.1.289.4 YES NO