FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)

SNMP Support
145SNMP Reference for Directors and Edge Switches
Port State Descriptions
FCEOS, Fibre Alliance M3.1.
The alert symbol is displayed on the corresponding port card in the Hardware
View, next to the specific port in the Port Card Detailed View, and in the Alert
column of the Port List View. It indicates that a corrective action is required to
return the port back to a normal operating state.
The FibreAlliance MIB connUnitPortStates are numbered as follows:
(1)unknown, (2)online, (3)offline, and (4)bypassed.
The FibreAlliance MIB connUnitPortStatus are numbered as follows:
(1)unknown, (2)unused, (3)ok, (4)warning, (5)failure, (6)notparticipating,
(7)initializing, and (8)bypassed.
The FibreAlliance connUnitPortHWStates are numbered as follows: (1)unknown,
(2)failed, (3)bypassed, (4)active, (5)loopback, (6)txfault, (7)noMedia, and
(8)linkDown
The FE MIB fcFxPortPhysOperStatus are numbered as follows: (1)online,
(2)offline, (3)testing, and (4)link-failure.
PortStatus
Used
internally
by HAFM
Displayed in
HAFM
FibreAlliance MIB**
FE
MIB***
Port
LED’
s
Description
Port
State
Alert
Symbol
*
connU
nitPort
State
connU
nitPort
Status
connU
nitPort
HWSta
te
fcFxPort
PhysOp
erStatus
G
r
e
e
n
A
m
b
e
r
STAT_NOT
_INSTALLED
Not
Installed
unkno
wn(1)
unkno
wn(1)
unkno
wn(1)
No table
entry
Port card not
installed.