FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)
SNMP Support
133SNMP Reference for Directors and Edge Switches
Port Table (Port Group)
fcEosFruStatus INTEGER R Identifies the operational status of the
module. The unknown(0) state indicates
that no information is available for the
FRU, which may happen when no FRU is
installed; The active(1) state indicates that
the current module is active; The backup(2)
state indicates that the backup module is
used; The update-busy (3) state indicates
that the module is in the updating process;
The failed(4) state indicates that the current
module is failed.
fcEosFruPartNumber DisplayString
(SIZE (0..64))
R The part number of the module. For the fan
FRU, the returned value is NULL.
fcEosFruSerialNumber DisplayString
(SIZE (0..64))
R The serial number of the module. For the
fan FRU, the returned value is NULL.
fcEosFruPowerOnHours Counter R The number of the hours that the FRU has
been in operation. For the fan FRU, the
returned value is NULL.
fcEosFruTestDate DisplayString
(SIZE (0..64))
R The final test date of the module. For the
fan FRU, the returned value is NULL.
FCEOS MIB Object
Name
Type Access Description
fcEosPortIndex fcEosPortInde
x
R Fixed physical port number on the switch.
It ranges from 1 to the number of physical
ports that can be supported in the switch.
fcEosPortPhyState fcEosPortPhyS
tate
R The physical state of the port.
fcEosPortOpStatus INTEGER R The operational status of the port. The
values are defined as follows: online(1),
offline(2), testing(3), and faulty(4). The
online(1) state indicates that user frames
can be passed. See “Port State
Descriptions” on page 145. If the port is
not installed, returns offline(2).