FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)

SNMP Support
113SNMP Reference for Directors and Edge Switches
FA MIB
Object
Name
Type Product Mapping Access Description
*fcConnUnitLi
nkIndex
Unsigned
32
A link index. R This value is used to create a
unique value for each entry
in the link table with the
same fcConnUnitId. The
value can only be reused if it
is not currently in use and
the value is the next
candidate to be used. This
value is allowed to wrap at
the highest value
represented by the number
of bits. This value is reset to
zero when the system is
reset, and the first value to
be used is 1.
FcConnUnitLi
nkNodeIdX
OCTET
STRING
(SIZE(16))
The WWN of the local
fcConnUnit is returned. This
information is available for
both E and F_Ports
R
The node WWN of the unit
at one end of the link. If the
node WWN is unknown and
the node is an fcConnUnit in
the responding agent, the
value of this object
must BE
equal to its fcConnUnitId.
FcConnUnitLi
nkPortNumbe
rX
Integer32 The fcConnUnit’s local port
number is returned. This
information is available for
both E and F_Ports.
R The port number on the unit
specified by
fcConnUnitLinkNodeIdX if
known, otherwise –1. If the
value is non-negative, it will
be equal to
fcConnUnitPortPhysicalNum
ber.
FcConnUnitLi
nkPortWwnX
OCTET
STRING
The local side port WWN
on the link. This information
is available for both E and
F_Ports.
R The port WWN of the unit
specified by
fcConnUnitLinkNodeIdX if
known, otherwise 16 octets
of binary 0.