FW V06.XX/HAFM SW V08.02.00 HP StorageWorks SNMP Reference for Directors and Edge Switches (AA-RQ7BE-TE, July 2004)
SNMP Support
105SNMP Reference for Directors and Edge Switches
FcConnUnitPo
rtControl
(continued)
(continued from previous
cell)
OnlineConnUnitPort (7): If
the addressed connectivity
unit allows this operation to
be performed on this port,
the addressed port performs
a vendor-specific "online"
operation. Examples of these
operations are: enabling a
port’s transceiver, the Link
Failure protocol, request
(participating) command to
the Loop Port state machine,
or addition of the port from
an arbitrated loop by a hub.
NOTE: Each implementation
may chose not to support
SNMP Set operations for any
or all of these values. For
Sets specifying varbinds for
instances of this object and
values not supported by a
given implementation, the
agent will return the SNMP
WrongValue PDU error
code.
FcConnUnitPo
rtName
SnmpAd
minString
Port Name R/W A string describing the
addressed port.