FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Embedded Web Server User Guide (AA-RTDRC-TE, July 2004)

Error Messages
168 Embedded Web Server User Guide
Error 157: Access Control
List is Disabled
The switch must be offline
and Fabric Binding must
be inactive before this
feature can be disabled.
Deactivating this feature
can be disruptive to
Fabric operations. Take
the switch offline and
deactivate fabric binding
before disabling this
feature.
Error 158: Invalid IP
Access Control List Pair
The pair of IP addresses
are invalid and cannot be
added to the list.
Make sure the IP
addresses are valid and
the first IP is lower than
the second
Error 159: Invalid IP
Access Control List Pairs
Count Value
The list being activated
has an invalid number of
IP pairs.
Make sure there is at least
one IP address in the
Access Control List.
Error 160: Management
Client IP Not Included In
IP Access Control List
The management
interface IP address is not
in the list.
The management IP must
be in the list or the current
connection would be lost.
Error 161: SANtegrity
Authentication feature key
must be uninstalled
The operation cannot be
completed with the
SANtegrity Authentication
key installed.
Remove the SANtegrity
Authentication feature
key.
Error 162: List is full There is no more room for
new entries in the list.
Remove a different entry
and try again.
Error 163: FICON MS
feature key must be
installed
The command is not
available without the
FICON MS feature key.
Install the FICON MS
feature key.
Error 164: FICON CUP
Zoning feature key must
be uninstalled
The operation cannot be
completed with the
FICON CUP Zoning key
installed.
Remove the FICON CUP
Zoning feature key.
Error 165: CUP Zoning
feature key must be
installed
The command is not
available without the
FICON CUP Zoning
feature key
Install the FICON CUP
zoning feature key.
Error 166: CUP Zoning
feature must be enabled
The command cannot be
completed with the CUP
Zoning feature enabled
Enable FICON CUP
Zoning.
Error 167: Diagnostics
can not be run on inactive
port
The port is in the inactive
state and diagnostics
can't be run.
The port state must
change out of the inactive
state.
Table 9: Embedded Web Server Messages (Continued)
Message Description Action