Monitoring Products
120 Embedded Web Server User Guide
Not installed The port optics are not installed or the feature that
provides additional port function is not enabled.
Not Operational The switch port is receiving the Fibre Channel not
operational sequence (NOS) indicating that the attached device is not
operational.
Online The attached device has successfully connected to the switch and
is ready to communicate or is in the process of communicating with other
attached devices.
Offline The switch port was configured as “blocked” and is
transmitting the Fibre Channel OLS to the attached device.
Port Failure The switch port has failed and requires service. (A port
in the failed state cannot beacon.)
Segmented E_Port The E_Port is segmented preventing the two
fabrics from joining (this only occurs when two switches are connected to
each other).
Testing Port is executing an internal loopback test.