FW 08.01.00 McDATA E/OS SNMP Support Manual (620-000131-630, November 2005)

B
Event Group
B-45
FC Management MIB
Access read-only
Status mandatory
Description This is the Fibre Channel ID of this port. If the connectivity unit is a
switch, this is expected to be a Big Endian value of 24 bits. If this is
loop, then it is the ALPA that is connected. If this is an eport, then it
will only contain the domain ID. If not any of those, unknown or
cascaded loop, return all bits set to 1.
Sequence
::= { connUnitLinkEntry 13 }
connUnitLinkCurrIndex
Syntax INTEGER
Access read-only
Status mandatory
Description The last used link index.
Sequence
::= { connUnitLinkEntry 14 }
The following four tables have been obsoleted. These were used to
keep statistic information based on the type of port type. It was
changed for all ports to use a common statistics table.
connUnitPortStatHubTable
Syntax SEQUENCE OF ConnUnitPortStatHubEntry
Access not-accessible
Status obsolete
Description A list of statistics for the hub port type.
Sequence
::= { statSet 1 }
connUnitPortStatFabricTable
Syntax SEQUENCE OF ConnUnitPortStatFabricEntry
Access not-accessible
Status obsolete
Description A list of statistics for the fabric port types.
Sequence