FW 08.01.00 McDATA E/OS Command Line Interface User Manual (620-000134-740, November 2005)

2
CLI Commands
2-5
config
show.port.profile on page 2-208
show.preferredPath.showPath on page 2-216
show.snmp.accessTable on page 2-223
show.snmp.targetTable on page 2-224
show.snmp.userTable on page 2-225
show.snmp.V3GroupTable on page 2-226
show.snmp.viewTable on page 2-227
show.syslog on page 2-234
config
The config branch of the CLI command tree contains commands that
set parameter values on the switch or director. These values are not
temporary (session) values, but are retained across power cycles.
The commands in the config branch can only be accessed by a user
with administrator level user rights. CLI commands are activated on
the switch immediately, except as noted.
In general, the config naming commands (except for the config.zoning
commands) use the USASCII character set. All of the characters in
this 128-character set (the first 7-bit subset of the ISO-8859-1 Latin-1
character set) are valid. Any exceptions are noted in the specific
command descriptions.
config.enterpriseFabMode.setState
Syntax setState enterpriseFabModeState
Purpose This command sets the Enterprise Fabric Mode state for the fabric.
The SANtegrity™ feature key must be installed to activate the
Enterprise Fabric Mode state.
NOTE: The command config.features.enterpriseFabMode on page 2-6 has
functionality that is identical to this command.