FW 08.01.00 McDATA E/OS Command Line Interface User Manual (620-000134-740, November 2005)
2
CLI Commands
2-187
show
show.frus
Syntax frus
Purpose This command displays information about all field-replaceable units
(FRUs).
Parameters This command has no parameters.
Command Example
Root> show frus
Output The FRU information is displayed as a table that includes the
following properties:
Output Example The output from the show.frus command appears as follows:
FRU Position State Serial Num Part Num Beacon Pwr On Hrs
----- -------- ------ -------------- --------- --------- ----------
CTP 0 Active 470-000399-700 123456789 Off 2800
CTP 1 Backup 470-000399-700 223456789 On 2801
SBAR 0 Active 470-000399-700 223456789 Off 2801
SBAR 1 Failed 470-000399-700 223456789 Off 2801
FPM 1 Active 470-000399-700 223456789 Off 2801
FPM 3 Active 470-000399-700 223456789 Off 831
UPM 4 Active 470-000399-700 223456789 Off 831
FRU The FRU name. (This may show Unknown or
Not Installed if the FRU is not installed.)
Position The relative position of the FRU, that is, its slot.
State The state of the FRU. Values are:
Active—the current module is active.
Backup—this module is not currently being
used, but it is available for immediate failover.
NotInst—the module is not currently installed.
Failed—the current module is failed.
Serial Num The serial number of the FRU. (This field is
blank for power supply modules of the
Sphereon 4300 and Sphereon 4500 switches.)
Part Num The part number of the FRU.
Beacon The beaconing state of the FRU (On or Off).
Pwr On Hrs The power-on hours value for the FRU.