FW 08.01.00 McDATA E/OS Command Line Interface User Manual (620-000134-740, November 2005)
2
CLI Commands
2-149
perf
• Class 2 Busied Frames
• Class 2 Rejected Frames
• Class 3 Discarded Frames
perf.thresholdAlerts.counter.addAlert
Syntax addAlert name
Purpose This command configures a new counter threshold alert and assigns
it a name. The new alert is assigned default settings which can then
be changed using the other counter threshold alert commands.
The default settings for a new counter threshold alert are as follows:
• Ports: None
• Counter: None
• Increment: 100
• Interval: 60 minutes
•State: Disabled
Parameters This command has one parameter:
TIP: Although the system supports a name length of 64 characters, you may want to
use a much shorter name. Some commands that display the threshold name show a
maximum of 51 characters. If you specify lengthy names, you can display the complete
name by entering the comma-delimited mode using the commaDelim command. For
more information, see Using the commaDelim Command on page 1-18.
Command Example Root> perf thresholdAlerts counter addAlert checklinks
name Specifies the name of the new counter
threshold alert. This name can consist of any
ASCII characters up to a maximum length of
64 characters. To use spaces or special
characters in this name, put quotation marks
around the name. This parameter is
case-sensitive.