FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZH-TE, August 2005)

If you are using the 1U rack-mount HAFM appliance to manage the director or edge
switch, the minimum HAFM version required is 07.02.00-9, which is the minimum version
installed. This HAFM software is contained on the HP StorageWorks ha-fabric manager
documentation and software CD (Part Number 516-000024-720).
The previous minimum versions of HAFM allow you to manage directors or edge
switches running 07.01.02-4 rmware, but to be able to use all the new features and
enhancements, you need to upgrade HAFM to 08.06.00, which runs only on the 1U
rack-mount HAFM appliance.
As an alternative, you ca n perform the rmware upgrade directly to the director or edge
switch using their EWS.
Please contact your local HP technical resource if you ne ed to obtain a new HAFM
version.
Please contact your local HP technical resource to conrm compatibility with devices
in your SAN before upgrading to this rmware version.
For more information on upgrading soft ware versions, refer to the HP StorageWorks
HA-Fabric Manager User Guide. The features of this software version are detailed in the
accompanying manuals listed in section Other edge switch documentation.
Zone FlexPar feature
Because zoni
ng is managed on a fabric-wide basis, a ll switches and directors in the
fabric must
maintain the same zoning conguration. This conguration is m aintained
automatically through the Fibre Channel protocol.
To keep this information current, RSCN messages are sent through the fabric to inform
attached devices when zoning changes occur, when devices become available, or
when devic
es become unavailable. In the case where devices become available or
unavailable, RSCNs are sent only to the devices in the same zone. Zoning changes,
however, trigger RSCNs to be sent to all of the devices in the fabric. As fabrics grow
larger and larger, the quantit y of RSCNs from zoning changes can create congestion
and disrupt devices, causing them to pause normal activity to determine the status of
the other devices. This can occur even if the new device is not zoned to talk to the
other devices in the fabric.
With th
e Zone FlexPar feature enabled, RSCN m essages for a zoning change are
handle
d like RSCNs for availability/unavailability changes. Specically, RSCNs are
restricted to only those devices sharing at least one common zone with the device that
changed. This way, only devices that are impacted by the change in connectivity
recei
ve RSCNs.
Edge Switch release notes