FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZH-TE, August 2005)

Downgrades directly to 05.03.01 from 06.xx.xx is not concurrent when the
second-generation Edge Switch 2/24 is congu red in Open Fabric operating
mode. In other words, downgrades in Open Fabric modecannotbedonewiththe
second-generation Edge Switch 2/24 online without disrupting port operations. Since
second-generation Edge Switch 2/24 switches cannot be downgraded earlier than
05.03.01, they must be congured in H om og e n eou s Fabric Interoperability mode to
remain concurrent. If this process is not followed, I/O through the switch may be
signicantly disrupted or stopped. Recovery for this situation is accomplished by
reactivating the current zone set.
If you are installing a n ew or replacement second-generation Edge Switch 2/1 2 or Edge
Switch 2/24 into an existing 05.xx.xx fabric, HP recommends that you downgrade
theunitbeforeinstallingitintothefabric.
Downgrading to 05.05.00 is suppor ted only on rst-generation Edge Switch 2 /12
switches. Second-generation Edge Switch 2/12 switches can be downgraded only to
05.05.01. Second-generation Edge Switch 2/24 switches can be downgraded only
to 05.03.01.
If a D irector 2/140 in a multiswitch fabric is downgraded earlier than 06.02.00, ISL s
could become segmented if there are any other switches in the fabric operating with a
rmware version e arlier than 06.01.00. To prevent this situation, downgrade all Director
2/140s in the fabric to 06.01.00 before downgrading any products in the fabric to
05.xx.xx. This problem only exists with Director 2/140s in the fabric. HAFM displays a
warning message if a downgrade from 06.02.00 is attempted, but you can continue
with the downgrade if desired.
NOTE:
The warning message is displayed when downgrading any model from 06.02.00, but
only applies to downgrade operations for the Director 2/140.
Firmware downgrades should not be performed using EWS and Internet Explorer
v5.00.3315.1000x. If this operation is performed, the download operation may not
complete and may eventually time-out le aving the switch with the previous version of
rmware .
HAFM upgrade required for rmw are version 07.xx.xx
To upgrade to rmware 07.01.02-4, you must rst upgrade the HAFM soft ware to
07.01.00-9 minimum, if you are using the notebook HAFM server to m a nage the
director or edge switch. The HAFM software is contained on the HP StorageWorks
ha-fabric manager documentation and software CD (Part Number 516-000024-820).
An upgrade kit to HAFM 07.01.00-9 is also available, Part Nu mber 320908-B22, for
owners of license for previous versions. This HA FM upgrade is also available on the
following HP web site: h
ttp://h18006.www1.hp.com/storage/sanin frastructure.html
12