FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZH-TE, August 2005)

If you get one of these messages during the upgrade, the rmware upgrade failed, but
the u nit continues working with the existing rmware without an interruption in service.
The upgrade process checks for sufcient memor y before activating the new rmware
image. The rmware upgrade do es not complete without suf cient memory. Please
contact HP Customer Support if you receive this message.
Upgrading rmw
areonanedgeswitchfrom04.xx.xxto05.xx.xx
An issue has bee
nidentied in release 04.xx.xx if the contents of the nonvolatile storage
(NVRAM) on the
CTP become corrupted. Once the conguration has been loaded,
this corrupt
ion is not detected until an I PL/IML, power cycle, or rmware code load.
If the NVRAM in the CTP has corrupted contents, the rmwar e load can cause the
conguration to reset to factory defaults, which could cause a sys tem outage.
Edge switch p
roducts already running 05.01.00 or later continually validate the NVRA M
congurati
on, so risk of an outage is extremely low. For edge switch products running an
earlier ver
sion of rmware, the risk of an outage increases due to the NVRAM issue. If
an outage c
ompromises system integrity, HP recommends tha t the edge switch rmware
upgrade b
e a scheduled maintenance action that anticipates the failure of switch
connect
ivity. This issue was corrected with rmwar e 05.02.00-13 and later.
To safely upgrade rmware on a e dge switch, perform the following:
1. Upgrade HA FM software on the HAFM server/appliance to 07.01.00 (minimum).
2. Download rmware 05.0 2.00-13 using the Firmware Library option under the
Product Manager Maintenance menu.
3. Backuptheedgeswitchconguration using the Backup & Restore Conguration
optio
n under the Product Ma nager Maintenance m enu.
4. Upgr
ade the rmware to 05.02.00-13 on each edge switch using the Send option
on the Firmware Library dialog box.
Considerations for downgrading the version of rmware
Directors or edge switches are not required to be ofinebeforeperformingarmware
downgrade operation. Limitations to downgrades are clearly identied if there are any
limitations to performing the operation.
Before downgrading rmware, it is highly recommended that you back up the director
or edge switch conguration. Refer to your H P StorageWorks Edge Switch Element
ManagerUserGuidefor more information. EWS also provides an option to print or
save product cong uration to a le. Refer to your H P StorageWorks Embedded Web
Server User Guide for m ore information.
10