FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks Edge Switch Release Notes (AA-RTDZH-TE, August 2005)

Prerequisites for i
nstalling and using rmware 07. 01.0 2
If you are using HAF
M, rmware 07.01.02 requires HAFM 07.01.00 or later (check with
HP Customer S uppo
rt for the latest shipping version of HAFM). HAFM should be at the
minimum level bef
ore installing the new rmware.
NOTE:
HAFM is not required for operating hardware products using the rmware.
All directors an d edge switches in the same fabric should have the same rmwar e level
installed. Although products may co-exist in a fabric running different levels of rmware,
all products must be at the same major functional release level.
Upgrading from an earlier version of rmwar e
Upgrading to rmware 07.01.02-4 is non-disruptive to attached devices. The director
or edge switch is not required to be ofine before performing an upgrade operation.
Limitations to upgrades are clearly identied if there are any limitations to performing
the operation.
Before upgrading rmware, it is highly recommended that you back up the director
or edge switch conguration. Refer to your HP StorageWorks Edge Switch Element
Manager User G uide for more information. Embedded Web Server (EWS) also provides
an option to print or save product con guration to a le. Refer to the HP StorageWorks
Embedded Web Server User Guide for m ore information.
All products must be running rmware 06.00.00 or later before upgrading to
07.01.02-4. If a switch is operating with a rmware level earlier than 06.00.00, you
mustupgradeto06.xx.xxbeforeinstalling07.01.02-4.
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.01.02-4. If EWS is used for upgrades and downgrades, and this
rule is not followed, errors occur and there may be a disruption to attached devices.
If upgrading to rmware 06.02.00-22 requires you to upgrade from 04.xx.xx to
05.xx.xx in the process, there are special considerations, as detailed in the section,
Upgrading rmware on an edge s w itch from 04.xx.xx to 05.xx.xx.
A sm all number of e arly-shipped Surestore Director FC-64 units may receive one of the
following messages when they upgrade to rmware 05.02.00-13:
HAFM—Firmware cannot be loaded due to insufficient CTP
memory.
EWS—File System Error: Insufficient memory for new
firmware version.
This occurs only in certain units with CTP cards. Units with CTP2 cards do not have
this issue.
Edge Switch release notes