FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
3-4
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
143 Low BB_Credit relieved on an ISL. No action required.
150 Zone merge failure. Go to MAP 0600.
151 Fabric configuration failure. Go to Collect Maintenance Data
on page 4-22.
300 Cooling fan propeller failed. Go to MAP 0400.
301 Cooling fan propeller failed. Go to MAP 0400.
302 Cooling fan propeller failed. Go to MAP 0400.
310 Cooling fan propeller recovered. No action required.
311 Cooling fan propeller recovered. No action required.
312 Cooling fan propeller recovered. No action required.
400 Power-up diagnostic failure. Go to MAP 0200.
410 Switch reset. No action required.
411 Firmware fault. Go to MAP 0200.
412 CTP watchdog timer reset. Go to Collect Maintenance Data
on page 4-22.
421 Firmware download complete. No action required.
423 CTP firmware download initiated. No action required.
426 Multiple ECC single-bit errors occurred. Go to MAP 0400.
433 Non-recoverable Ethernet fault. Go to MAP 0400.
440 Embedded port hardware failed. Go to MAP 0400.
442 Embedded port anomaly detected. No action required.
445 ASIC detected a system anomaly. No action required.
453 New feature key installed. No action required.
506 Fibre Channel port failure. Go to MAP 0500.
507 Loopback diagnostics port failure. Go to MAP 0500.
508 Fibre Channel port anomaly detected. No action required.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code Explanation Action