FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
2
Installation Tasks
2-27
Installation Tasks
Figure 2-16 Configure Panel (Security Page with Port Binding Tab)
a. Click the check box in the Port Binding column to enable or
disable port binding for a specified port (default is disabled).
b. In the Bound WWN column, type the world wide name of the
device to which the port is to be bound. If port binding is
enabled, only the specified device can connect to the port. If
port binding is enabled and no device is specified in the Bound
WWN column, then no devices can connect to the port.
c. The Attached WWN column contains read-only fields that list
the world wide names of attached Fibre Channel devices.
Click the check box in the Use Attached column to indicate the
world wide name specified in the Attached WWN column is to
be used for port binding. After activation, the attached WWN
appears in the Bound WWN column.
2. Click Activate to save the information. The message Your changes
to the port binding configuration have been successfully
activated appears.
Configure Switch
Binding
Perform this procedure to configure switch binding by attached
devices (nodes). The SANtegrity™ binding feature must be installed
to access this control. Refer to Install PFE Keys (Optional) on page 2-38
for instructions. If the feature is not installed, the message This
Feature Not Installed appears.