FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
2
Installation Tasks
2-17
Installation Tasks
Figure 2-9 Configure Panel (Switch Page with Fabric Parameters Tab)
a. At the R_A_TOV field, type a value between 10 through 1200
tenths of a second (one through 120 seconds). Ten seconds
(100) is the recommended value.
NOTE: If the switch is attached to a fabric element, the switch and
element must be set to the same R_A_TOV value. If the values are not
identical, the E_Port connection to the element segments and the
switch cannot communicate with the fabric. In addition, the
R_A_TOV value must be greater than the E_D_TOV value.
b. At the E_D_TOV field, type a value between 2 through 600
tenths of a second (0.2 through 60 seconds). Two seconds
(20) is the recommended value.
NOTE: If the switch is attached to a fabric element, the switch and
element must be set to the same E_D_TOV value. If the values are not
identical, the E_Port connection to the element segments and the
switch cannot communicate with the fabric. In addition, the
E_D_TOV value must be less than the R_A_TOV value.
c. Select from the Switch Priority drop-down list to set the switch
priority. Available selections are Default, Principal, and Never
Principal. The default setting is Default.