FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
2
2-4
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Installation Tasks
Unpack and Inspect
the Switch
Unpack and inspect the switch(es) as follows:
1. Inspect shipping container(s) for damage caused during transit. If
a container is damaged, ensure a representative from the freight
carrier is present when the container is opened.
2. Unpack shipping container(s) and inspect each item for damage.
Ensure the packaged items correspond to the items listed on the
enclosed bill of materials.
3. If any items are damaged or missing, contact the McDATA
solution center as follows:
Phone: (800) 752-4572 or (720) 566-3910
Fax: (720) 566-3851
E-mail: support@mcdata.com
Desktop Installation
To install the switch on a desktop:
1. Remove the backing from the four adhesive rubber pads and
apply the pads to the underside of the switch. Ensure the pads
are aligned with the scribed circles at each corner.
2. Position the switch on a table or desktop as directed by the
customer. Ensure:
— A grounded AC electrical outlet is available.
— Adequate ventilation is present, and areas with excessive
heat, dust, or moisture are avoided.
— All planning considerations are met. Refer to McDATA
Products in a SAN Environment - Planning Manual (626-000124)
for information.
3. Verify all small form factor pluggable (SFP) optical transceivers
are installed as ordered.
4. Connect the AC power cord to the receptacle at the rear of the
chassis as shown in Figure 2-1 on page 2-5.
5. Connect the AC power cord to a facility power source that
provides single-phase, 100 to 240 volt alternating current (VAC)
current.