FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual (620-000171-010, April 2005)
1
1-8
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
General Information
Storage and Shipping
Environment
Protective packaging must be provided to protect the switch under
all shipping methods (domestic and international).
Shipping temperature:
-40
0
F to 140
0
F (-40
0
C to 60
0
C)
Storage temperature:
34
0
F to 140
0
F (1
0
C to 60
0
C)
Shipping relative humidity:
5% to 100%
Storage relative humidity:
5% to 80%
Maximum wet-bulb temperature:
84
0
F (29
0
C)
Altitude:
40,000 feet (12,192 meters)
Operating
Environment
Temperature:
40
0
F to 104
0
F (4
0
C to 40
0
C)
Relative humidity:
8% to 80%
Maximum wet-bulb temperature:
81
0
F (27
0
C)
Altitude:
10,000 feet (3,048 meters)
Maintenance Approach
Whenever possible, the switch maintenance approach instructs
service personnel to perform fault isolation and repair procedures
without degrading or interrupting operation of the switch, attached
devices, or associated applications. Switch fault isolation begins
when one or more of the following occur: